A wide QRS complex is very uncommon in DHF patients, therefore, t

A wide QRS complex is very uncommon in DHF patients, therefore, the QRS duration is not a major determinant for the presence of systolic and diastolic dyssynchrony. Unlike patients with SHF, selleck screening library mechanical dyssynchrony in DHF may occur as a result of myocardial disease rather than electromechanical coupling delay. Coexistence but not cause-effect relationship of cardiac dysfunction

and mechanical dyssynchrony was described in previous Inhibitors,research,lifescience,medical studies, while the correlation between the two facets of LV performance differed among studies.11-13),71) Therefore, apart from the severity of myocardial dysfunction, dyssynchronous LV relaxation and impairment of ventricular restoring forces may also interfere the LV filling and lead to a diastolic dyssynchrony,72) or vice versa. Interestingly, medical therapy for DHF, including diuretics, beta-blockers, Inhibitors,research,lifescience,medical calcium-channel blockers, angiotensin-converting enzyme inhibitors and/or angiotensin-receptor blockers, was associated with shortening of diastolic intraventricular delay, which in turn correlated with improvement of Inhibitors,research,lifescience,medical LV stiffness and reduction of filling pressure.12) However, it remains to define what extent LV dyssynchrony is involved in the pathophysiologic mechanism of DHF. Dyssynchrony and Mortality in Heart Failure The prognostic implication of mechanical

dyssynchrony was initially reported by Bader et al.73) where 104 CHF patients with ejection fraction ≤ 45%, over half of them had wide QRS complexes, were examined by the use of pulsed TDI and followed up for one year. Although no mortality occurred at the end of follow up, 86 patients (83%) were admitted for decompensated CHF. As a result, intraventricular dyssynchrony was found Inhibitors,research,lifescience,medical to be most important independent predictor of heart Inhibitors,research,lifescience,medical failure hospitalization, and the other two independent predictors included LV ejection fraction and QRS width. In another early study of 106 CHF patients with LV ejection fraction < 35% and QRS duration ≤ 120 ms who were followed up for a mean of 17 ± 11 months, intraventricular dyssynchrony was measured by TDI as the Ts-SD from both basal and middle LV segments in apical

4- and 2-chamber views. A Ts-SD cutoff value of > 37 ms was associated with a significant increase in clinical event of including heart Astemizole failure hospitalization or cardiac transplantation.74) The same group recently published their study on 167 CHF patients with a mean follow up of 33 months. Electrical dyssynchrony defined as the QRS duration ≥ 120 ms and mechanical delay as the septal-to-lateral wall delay ≥ 65 ms were investigated for their association with adverse events.75) In multivariate Cox regression analysis, the septal-to-lateral wall delay [hazard ratio (HR), 2.37; p = 0.002] showed a better predictive value than QRS duration (HR, 1.88; p = 0.028) for cardiac events. Moreover, patients with both electrical and mechanical dyssynchrony had a HR of 3.98 (p < 0.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>