However, the exact mechanism of adhesion

However, the exact mechanism of adhesion GW-572016 order has yet to be determined because of the complex combination of numerous other factors related to the bacteria itself, the in vivo environment and the particular artificial material involved. BioSelleckchem HKI-272 Materials used for clinical purposes are strictly regulated through standards such as the International

Organization for Standardization (ISO) and the American Society for Testing and Materials (ASTM). Biomaterials can be made of just a few kinds of standardized materials depending on their application, including titanium, stainless steel, and cobalt-chromium-molybdenum alloy (Co-Cr-Mo). Oxinium is an oxidized zirconium-niobium alloy commercialized as a new biomaterial in Japan in 2008. It is created by permeating

a zirconium-niobium alloy with oxygen at a high PCI-34051 ic50 temperature so that the surface is changed to a monoclinic zirconia ceramic with a depth of only 5 μm. As a result, Oxinium has the low abrasiveness on sliding surfaces of a ceramic, but has the strength of a metal. It also contains almost no toxic metals [21]. Steinberg et al. reported differences in bacterial adhesion to two different material surfaces, titanium and titanium alloy [22]. Recently, there have been a number of reports on the impact of the physical properties of the solid materials themselves on bacterial Montelukast Sodium adhesion [23-31] and a particularly strong relationship between bacterial adhesion and surface roughness has been highlighted [28-31]. Rougher surfaces have a greater surface area and the depressions in the roughened surfaces can provide more favorable sites for colonization. Some previous reports have shown that bacterial adhesion in vivo is primarily determined by a surface

roughness of Ra greater than 0.2 μm (200 nm) [32,33]. On the other hand, Lee et al reported in an in vitro study that the total amount of bacteria adherent on resin (Ra = 0.179 μm) was significantly higher than on titanium (Ra = 0.059 μm) or zirconia (Ra = 0.064 μm). However, they also demonstrated no significant difference between titanium and zirconia [34]. Öztürk et al indicated that the roughness difference of 3 to 12 nm Ra between as-polished and nitrogen ion-implanted Co-Cr-Mo contributes to bacterial adhesion behavior [35]. Thus, a general consensus has not been yet obtained in the literature regarding the minimum level of roughness required for bacterial adhesion. Furthermore, there are few studies that compare bacterial adherence capability on the same types of biomaterial that differ in surface roughness on the nanometer scale (Ra < 30 nm). To our knowledge, no other studies have been carried out to date that simultaneously evaluate the bacteriological characteristics of adhesion to five different types of material, including Oxinium.

Comments are closed.