We present a case report of a renal transplant patient with a heavily encrusted forgotten stent. We employed a simultaneous approach, Proteasomal inhibitor using percutaneous nephrostolithotomy and cystolithalapaxy, for complete removal of the encrusted stent and associated stones. A MEDLINE literature review was then performed to identify and analyze similar cases in which a forgotten stent in a renal allograft was removed. Our experience and that found in the medical literature suggest that removal of forgotten stents can be achieved safely and effectively with proper
endourological techniques. We also reviewed the current status of ureteral stent design in terms of attempts to preclude this problem. Ureteral stent design is still in a state of evolution with a focus on creating stents of new materials, and stents with new coatings, that may prevent encrustation.”
“PURPOSE: To assess the performance of a partial coherence interferometry Crenolanib clinical trial (PCI)-based device for the determination of anterior segment biometry.
SETTING: Clinica Centrofama, Cartagena, Murcia, Spain.
METHODS: Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with
the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with Dinaciclib Cell Cycle inhibitor and without cycloplegia. The same measurements were performed in additional subjects.
RESULTS:
Twenty-one eyes (16 subjects) were evaluated. Repeated measurements of the single subject yielded a standard deviation of 4.0 mu m for CCT, 106.0 mu m for ACD, and 323.0 mu m for LT; there were many peaks, mainly in the last 10 readings. There was a high correlation between CCT measurements with both systems with and without cycloplegia (r(2)> 0.93), with the US system giving higher values. Differences were significant (P <.001), but not consistent, throughout the range of corneal thicknesses and were greater for thicker corneas. Differences in ACD and LT measurements were similar. Agreement between systems in ACD and LT measurements was considerably lower than for CCT measurements.
CONCLUSIONS: The PCI biometer provided precise CCT measurements. The ACD and LT measurements had a higher variance. Differences in CCT measurements between the 2 systems were greater for thicker corneas, with higher values with the US system.”